Product Information

SITAU FP (Full Parallel) is undoubtedly the most advanced technology of the SITAU series, allowing simultaneous control of up to 128 Ultrasound channels in both emission and reception. It is the ideal solution for phased array inspections requiring active apertures larger than 32 elements.

SITAU FP, along with provided Matlab, Labview and C++ libraries, is a powerful tool for Ultrasound Laboratories and Research Centers, providing the maximum flexibility in both excitation of array elements and acquisition of received signals. Signals received by each one of the array elements can simultaneously acquired and stored, so that Synthetic Aperture Techniques (SAFT) can be implemented.

Main Features:

  • Up to 128 active channels
  • Phased Array and Parallel Acquisition operation modes.
  • Programmable gain up to 100 dB, with arbitrary TGC function.
  • Programmable width excitation pulse: Single, Burst and Coded Excitation.
  • Pulse-Echo and Pitch-Catch (or through transmission) modes.
  • Up to 16384 focal laws per image (Progressive Focusing Technique)
  • Non-peak-loss data reduction algorithm and Electromagnetic Interference Filter (EMI)
  • 4 Encoder inputs, External Trigger input and Synchronism output.
  • Libraries for Matlab, Labview and C++.

Images

sitau_FP

Downloads

TECHNICAL FEATURES:

PDF Technical Datasheet

MANUALES:

PDF Saft Library v1.2

CONTACTO:

Contact with DASEL